4
L-A2-256
Rev 5 - 1310220810
CHECK TO BE SURE THAT THE PROPER FUEL GAS IS BEING USED WITH THIS PILOT KIT.
The installation, including provisions for combustion and ventilation air, must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code (ANSI Z223.1/NFPA 54).
This component and its individual shutoff valve must be disconnected from the gas-supply piping system when
testing at pressures that exceed
1
/
2
psig. This is accomplished by closing the gas-supply line valve.
This component must be isolated from the gas-supply piping system by closing its individual manual shutoff
valve during any testing of the gas-supply system at test pressures up to and including
1
/
2
psig.
A fi replace screen must be in place when the gas burner system is in operation. Unless other provisions for
combustion air are provided, the screen shall have an opening(s) for introduction of combustion air.
WHEN GLASS FIREPLACE ENCLOSURES (DOORS) ARE USED, OPERATE THE BURNER SYSTEM WITH
THE GLASS DOORS FULLY OPEN; BOTH SIDES IF THE FIREPLACE IS A SEE-THROUGH TYPE.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home where not
prohibited by local codes. Installation of appliances designed for manufactured homes or mobile homes must
conform with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 in the U.S.; or with
CAN/CSA Z240 MH in Canada; or with ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard when such as standard is not applicable.
Do not use this appliance if any part has been underwater. Immediately call a qualifi ed service technician to
inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
IMPORTANT INFORMATION
SPECIFICATIONS
Table 2 - Maximum BTUs
Minimum fi rebox dimensions required for burner system
(with APK valve attached):
Burner size
Min. Firebox Dimensions
Center Width * Depth Height
16/19" 30" 11" 18"
18/20" 31" 14" 18"
24" 35" 14" 18"
30" 41" 15" 18"
36" 47" 16" 18"
42" 53" 16" 18"
48" 59" 16" 18"
54" 65" 16" 18"
60" 71" 16" 18"
* This required width allows for centering of the log set.
Table 1 - Minimum Firebox Dimensions
Center width
Depth
Model
BTUs
Nat. L.P.
APK-17 100 k 200 k
ALWAYS KEEP GRANULES AND ALL FOREIGN OBJECTS AWAY FROM THE PILOT
ASSEMBLY AND VALVE ASSEMBLY.
IT IS CRITICAL THAT THE HEAT SHIELD BE PLACED CORRECTLY OVER THE VALVE
FOR THE UNIT TO OPERATE CORRECTLY.