TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
1. Pilot will not light a. Obstruction in pilot gas supply or
pilot gas-supply line is kinked
b. Inadequate gas supply
c. Air in line
a. Clear out obstruction. Replace pilot gas-
supply line if kinked
b. Have gas pressure checked by installer
or gas supplier
c. Air should clear; attempt to relight
2. Pilot will not stay lit after
releasing knob
a. Thermocouple connection to valve
either too tight or too loose
b. Bad thermocouple
a. Thermocouple should be fi nger tight and
then
1
/
8
" turn with a wrench
b. Replace thermocouple
3. Log set extinguishes
a few minutes after
lighting
a. Inadequate gas supply causes
pilot fl ame to reduce after burner
lights
a. Using pilot adjustment, increase gas to
pilot. Pilot fl ame must be in contact with
the thermocouple tip.
4. Log set extinguishes
after burning for some
time (approximately 10
minutes to 1 hour)
a. Thermocouple has overheated;
glass doors are closed
b. Thermocouple has overheated;
insulation pad is not in place
c. Thermocouple has overheated;
burner flames are heating the
thermocouple cold junction
a. Be sure glass doors are open during
operation
b. Be sure that the insulation pad is in place
between the burner pan and the pilot
bracket
c. Be sure the pilot assembly and the fl ame
diverter are in their proper position.
Re-arrange logs so that fl ame is not
defl ected to the thermocouple.
5. Valve will not turn "OFF"
with remote
a. Valve over heated
b. Low batteries
a. Ensure that the valve heat shield is
properly placed and no gas leaks are
present at the valve gas fi ttings
b. Replace batteries in remote receiver